TGRBH NG and TGRH NG

Pressurised electric water heaters

TGR range of water heaters have been expanded with models for horizontal wall installation. Water inlet and outlet pipes placed on the body of the tank allow quick and easy connection to the water supply mains. They are intended for supply of individual outlets as well as for central hot water supply from a single heater. The control knob located on the protective cover on the left side of the heater allows setting the water temperature up to 65 °C, as well as to choose an economical setting or the freeze prevent setting. The heaters are fitted with a copper immersion heating element for strong corrosion resistance and a long useful life.

AVAILABLE MODELS:

  • TGRBH NG - Horizontal wall mounting water heater with 40mm insulation thickness
  • TGRH NG - Compact dimensions Horizontal wall mounting water heater available outside

ADVANTAGES:

  • Supply of several outlets
  • Horizontal wall mounting
  • Electric immersion heating element
  • Temperature regulation with a control knob
  • Available temperature settings:
    • user-defined setting up to 65 °C
    • economical setting of 55 °C
  • Freeze protection 10 °C
  • Signal light for heating element operation display
  • Bimetal thermometer for display of water temperature in the heater tank
  • Working pressure 6 to 9 bar
  • Anti-corrosion tank protection with enamel and a magnesium anode
  • Available volumes/capacities:
    TGRBH NG: 50 l, 80 l, 100 l, 120 l, 150 l
    TGRH NG: 50 l, 80 l, 100 l, 120 l
  • Simple installation and maintenance

Properties

MODEL TGRBH 50 NG TGRBH 80 NG TGRBH 100 NG TGRBH 120 NG TGRBH 150 NG
Declared load profile S M M M L
Energy efficiency class (1) D D D D D
Energy efficiency ƞwh (1) (%) 29,9 34,4 33,9 33,3 34,4
AEC annual electricity consumption (1) (kWh) 617 1492 1514 1540 2900
Daily electricity consumption Qelec (2) (kWh) 3,021 7,08 7,207 7,359 14,12
Thermostat temperature settings eco eco eco eco eco
Specific precautions (assembly, install, maintain) When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory
Value of smart - - - - 0
Storage volume V (l) 47 76,1 96,1 116,4 145,5
Mixed water at 40°C V40 (2) (l) - 67,4 81 105 130
PURPOSE          
One or more outlets + + + + +
Vertical wall mounting + + + + +
DIMENSIONS OF CONNECTIONS          
Height (mm) 590 810 955 1110 1325
Diameter (mm) 500 500 500 500 500
Depth (mm) 507 507 507 507 507
Connections to the supply network G 1/2 G 1/2 G 1/2 G 1/2 G 1/2
Net/gross weight/with water (kg) 27/30/77 33/36/113 38/41/138 43/47/163 49/54/199
TECHNICAL CHARACTERISTICS          
Working pressure (MPa(bar)) 0,6(6)/ 1(10) 0,6(6)/ 1(10) 0,6(6)/ 1(10) 0,6(6)/ 1(10) 0,6(6)/ 1(10)
Enamelled steel tank + + + + +
Protective magnesium anode + + + + +
Selection of temperature up to 65°C + + + + +
Heating element control lamp + + + + +
Protection against freezing + + + + +
Thermometer + + + + +
Average thickness of insulation (mm) 40 40 40 40 40
Degree of protection IP 23 IP 23 IP 23 IP 23 IP 23
ELECTRICAL CONNECTIONS          
Rated power output (W) 2000 2000 2000 2000 2000
Voltage 230 V ~ + + + + +
Nominal current (A) 8,7 8,7 8,7 8,7 8,7
FUNCTIONAL CHARACTERISTICS          
Thermal losses at 65°C (3) (kWh/24) 1,13 1,4 1,46 1,7 1,85
Heating time from 10 to 65°C 1 h 38 min 2 h 37 min 3 h 16 min 3 h 55 min 4 h 54 min
TRASNPORTATION DATA          
Packaging dimensions (mm) 600 x 600 x 682 600 x 600 x 905 600 x 600 x 1050 600 x 600 x 1205 600 x 600 x 1420
(1) EU Regulation 812/2013; EN 50440
(2) EN 50440
(3) Measured at 20°C ambient temperatur e and 65°C water temperatur e in the heater (SIST EN 60379:2005 standar d).
MODEL TGRH 50 NG TGRH 80 NG TGRH 100 NG TGRH 120 NG
Storage volume V (l) 50 80 100 120
Mixed water at 40°C V40 (2) (l) - 67,4 81 105
PURPOSE        
One or more outlets + + + +
Vertical wall mounting + + + +
DIMENSIONS OF CONNECTIONS        
Height (mm) 570 775 935 1090
Diameter (mm) 454 454 454 454
Depth (mm) 461 461 461 461
Connections to the supply network G 1/2 G 1/2 G 1/2 G 1/2
Net/gross weight/with water (kg) 21/23/71 27/29/107 31/33/131 35/38/155
TECHNICAL CHARACTERISTICS        
Working pressure (MPa(bar)) 0,6(6)/ 1(10) 0,6(6)/ 1(10) 0,6(6)/ 1(10) 0,6(6)/ 1(10)
Enamelled steel tank + + + +
Protective magnesium anode + + + +
Selection of temperature up to 65°C + + + +
Heating element control lamp + + + +
Protection against freezing + + + +
Thermometer + + + +
Average thickness of insulation (mm) 17 17 17 17
Degree of protection IP 23 IP 23 IP 23 IP 23
ELECTRICAL CONNECTIONS        
Rated power output (W) 2000 2000 2000 2000
Voltage 230 V ~ + + + +
Nominal current (A) 8,7 8,7 8,7 8,7
FUNCTIONAL CHARACTERISTICS        
Heating time from 10 to 65°C 1 h 38 min 2 h 37 min 3 h 16 min 3 h 55 min
Amount of available mixed water at 40°C (1) (l) 80 130 174 210
Thermal losses (2) (kWh/24) 1,45 2,1 2,45 2,9
TRASNPORTATION DATA        
Packaging dimensions (mm) 480 x 490 x 595 480 x 490 x 800 480 x 490 x 960 480 x 490 x 1115
(1) Values are valid for mixing water with a temperatur e of 15°C from the cold inlet with water at 65°C fr om the heater (SIST EN 60379:2005 standar d).
(2) Measured at 20°C ambient temperatur e and 65°C water temperatur e in the heater (SIST EN 60379:2005 standar d).
MODEL TGRBH 50 NG / TGRH 50 NG TGRBH 80 NG / TGRH 80 NG TGRBH 100 NG / TGRH 100 NG TGRBH 120 NG / TGRH 120 NG TGRBH 150 NG / TGRH 150 NG
A (mm) 572 778 938 1093 1307
B (mm) 25 122,5 192,5 265 357,5
C (mm) 185 190 200 205 220
D (mm) 145 345 495 645 845