Pressurised electric water heaters
Besides the new and advanced electronic regulator with touch sensitive LCD the OGB SMART heaters boast top notch technical solutions for its heating elements. Tubular air heating elements are inserted into the metal protective tube of the heating flange. Both the tank and the protective tube are well enamelled, and along with the magnesium anode, they provide excellent anti-corrosion protection, reduce limestone depositing and simplify maintenance.
OGB SMART series heaters feature the behaviour monitoring/recording function which calculates after a certain period of time the optimum operating regime which allows minimum power consumption required to meet the user’s needs. Within a period of 7 days, the heater memorizes in which times of day the users require the largest amount of hot water, or at which times hot water consumption is the highest. In the SMART operating mode, the water heater thus uses the memorized data to switch on just soon enough to heat the water when the user needs it. This saves a considerable amount of power as the heater does not maintain a constant temperature (e.g. 60°C) as with standard settings; however, the amount of hot water and its temperature is still adequate for the user’s regular needs.
ADVANTAGES:
- Volumes: 80, 100, 120 and 150 l.
- Vertical wall mounting.
- High quality insulation for minimum heat loss.
- Indirect air heating elements.
- Tank made of a high quality steel sheet, enamel coated at 850°C.
- Mg anode for additional anticorrosion protection of the tank.
- Optional setting of water temperature up to 85°C.
- Large diameter of heating flange (100 mm) enables simple cleaning and maintenance.
- Simple installation and maintenance.
|
|
|
Properties
Declared load profile |
M |
L |
L |
XL |
Energy efficiency class (1) |
B |
C |
C |
C |
Energy efficiency ƞwh (1) (%) |
40,9 |
41,6 |
40,5 |
39,6 |
AEC annual electricity consumption (1) (kWh) |
1255 |
2464 |
2529 |
4224 |
Daily electricity consumption Qelec (2) (kWh) |
6,675 |
12,886 |
13,342 |
20,701 |
Thermostat temperature settings °C |
60 |
60 |
60 |
60 |
Specific precautions (assembly, install, maintain) |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
*Value of smart |
1 |
1 |
1 |
0 |
Weekly electricity consumption with smart control Qelec, week, smart (kWh) |
23,794 |
48,040 |
49,540 |
85,202 |
Weekly electricity consumption without smart control Qelec, week (kWh) |
27,949 |
55,832 |
57,632 |
91,701 |
Storage volume V (l) |
78,0 |
97,3 |
118,1 |
147,1 |
Mixed water at 40°C V40 (2) (l) |
116 |
137 |
172 |
213 |
PURPOSE |
|
|
|
|
One or more outlets |
+ |
+ |
+ |
+ |
Vertical wall mounting |
+ |
+ |
+ |
+ |
DIMENSIONS OF CONNECTIONS |
|
|
|
|
Height (mm) |
830 |
975 |
1130 |
1345 |
Width (mm) |
500 |
500 |
500 |
500 |
Depth (mm) |
512 |
512 |
512 |
512 |
Connections to the supply network |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
Net/gross weight/with water (kg) |
36/39/116 |
41/44/141 |
46/49/166 |
52/56/202 |
TECHNICAL CHARACTERISTICS |
|
|
|
|
Working pressure (Mpa(bar)) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
Enamelled steel tank |
+ |
+ |
+ |
+ |
Protective magnesium anode |
+ |
+ |
+ |
+ |
Degree of protection |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
FUNCTIONS OF ELECTRONIC REGULATION |
|
|
|
|
Touch – screen LCD display |
+ |
+ |
+ |
+ |
Heater on/off button |
+ |
+ |
+ |
+ |
Manual temperature setting up to 85°C |
+ |
+ |
+ |
+ |
Display of temperature setting and actual temperature of water in the heater |
|
|
|
|
+ |
+ |
+ |
+ |
|
Indication of heating element operation |
+ |
+ |
+ |
+ |
Indication of the amount of available water in the heater |
+ |
+ |
+ |
+ |
Recording of user habits – SMART function |
+ |
+ |
+ |
+ |
Several day absence setting |
+ |
+ |
+ |
+ |
Time management |
+ |
+ |
+ |
+ |
Fast heating |
+ |
+ |
+ |
+ |
Error diagnostic |
+ |
+ |
+ |
+ |
ELECTRICAL CONNECTION |
|
|
|
|
Number of heating elements x power (W) |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
Rated power output (W) |
2000 |
2000 |
2000 |
2000 |
Voltage 230 V ~ |
+ |
+ |
+ |
+ |
Nominal current (A) |
8,7 |
8,7 |
8,7 |
8,7 |
FUNCTIONAL CHARACTERISTICS |
|
|
|
|
Thermal losses at 65°C (3) (kWh/24) |
0,86 |
1,02 |
1,17 |
1,41 |
Heating time from 10 to 85°C |
3h 34min |
4h 27min |
5h 20min |
6h 10min |
TRANSPORTATION DATA |
|
|
|
|
Packaging dimensions (mm) |
575x600x940 |
575x600x1085 |
575x600x1240 |
575x600x1455 |
(1) EU Regulation 812/2013; EN 50440
(2) EN 50440
(3) Measured at 20°C ambient temperatur e and 65°C water temperatur e in the heater (SIST EN 60379:2005 standar d).
* information on water heating ener gy efficiency and annual electricity consumption r elate to enabled smart contr ol settings only
A (mm) |
830 |
975 |
1130 |
1345 |
B (mm) |
600 |
750 |
900 |
1100 |
C (mm) |
260 |
255 |
260 |
275 |
E (mm) |
100 |
100 |
100 |
100 |
F (mm) |
100 |
100 |
100 |
100 |
G (mm) |
320 |
320 |
320 |
320 |
|