OGB EDD 30-200

Pressurised electric water heaters

  • Volumes: 30, 50, 80, 100, 120, 150, 200 l.
  • Vertical wall mounting.
  • Original angular design.
  • High quality insulation assures lower heat loss.
  • Indirect air heating elements.
  • Tank made of a high quality steel sheet, enamel coated at 850°C.
  • Mg anode for additional anti-corrosion protection of the tank.
  • Bimetal thermometer.
  • Large diameter of heating flange (100 mm) enables simple cleaning and maintenance.
  • Simple installation and maintenance

Electronic controller

  • Mg anode consumption measurement.
  • Electrical heating element operation indicator.
  • Temperature range adjustment 35°C to 75°C (accuracy 1°C).
  • Temperature selection (menu button):
    • arbitrary temperature setting up to 85˚C (1˚C accuracy)
    • freeze protection (7°C)
    • economical temperature (55°C)
    • manual mode selection
    • water heater “On” or “Off “ selection.
  • Numerical display:
    • displays actual temperature in water heater
    • thermostat / thermometer sensor failure
    • extremely low temperatures
    • overheating (actual temperature exceeds 99˚C).

Indirect air heating elements – reliable operation, simple maintenance

Tubular air heating elements are inserted into the heating flange made of special steel and enamelled against corrosion. Compared to conventional immersion heating elements, the advantages of indirect heating element are as follows:

  • the heating elements are not in direct contact with water,
  • the replacement of heating elements is simple as it is not required to empty the water heater before repair,
  • the heating flange incorporates 2 or more heating elements electrically connected in parallel, assuring a higher reliability of operation (if one heating element fails, the water heater still operates),
  • the limestone depositing is reduced and removing the limestone deposit is simpler,
  • the inside surface is completely enamel coated (no blank surfaces, compared to the models with immersion heating elements) therefore Mg anode consumption is reduced and consequently its life span is longer.

Properties

MODEL OGB 30
EDD
OGB 50
EDD
OGB 80
EDD
OGB 100
EDD
OGB 120
EDD
OGB 150
EDD
OGB 200
EDD
Volume [l] 30 50 80 100 120 150 200
Purpose              
One or more outlets
Vertical wall mounting
Number of persons – average consumption 1 2 3 - 4 4 - 5 5 - 6 6 - 8 8 - 10
Dimensions of Connections              
A (mm) 510 690 830 975 1130 1345 1563
B (mm) 310 400 600 750 900 1100 1100
C (mm) 235 240 260 255 260 275 493
Connections to the supply network G 1/2 G 1/2 G 1/2 G 1/2 G 1/2 G 1/2 G 1/2
Net / gross weight / with warter [kg] 23/26/53 30/33/80 36/39/116 41/44/141 46/49/166 52/56/202 78/82/278
Technical Characteristics              
Working pressure [bar] 6 6 6 6 6 6 6
Enamelled steel tank
Magnesium protective anode
Selection of temperatures to 75 °C
Heating element control lamp
Signal lamp - demonstration of the heater
Thermometer
Average thickness of insulation [mm] 55 - 100 40 - 85 40 - 85 40 - 85 40 - 85 40 - 85 25 - 70
Degree of protection against humidity IP 24 IP 24 IP 24 IP 24 IP 24 IP 24 IP 24
Electrical Characteristics              
Rated power output [W] 2100 2000 2000 2000 2000 2000 2000
Voltage 230 V ~
Functional Characteristics              
Heating time from 15 to 75 °C 1h 05min 1h 55min 3h 05min 3h 55min 4h 35min 5h 45min 7h 40min
Amount of available mixed water at 40 °C [l]¹ 54 96 151 199 238 296 394
Thermal losses [kWh per 24 h]² 0,55 0,62 0,86 1,02 1,17 1,41 2,10
Transportation              
Packaging dimensions [mm] 575 x 600 x 620 575 x 600 x 720 575 x 600 x 940 575 x 600 x 1085 575 x 600 x 1240 575 x 600 x 1415 575 x 600 x 1673

(1) Values are valid for mixing water with a temperature of 15°C from the cold inlet with water at 65°C from the heater
(standard SIST EN 60379:2005).
(2) Measured at 20°C ambient temperature and 65°C water temperature in the heater (standard SIST EN 60379:2005).
* When connected as pressurised, use of safety valve is mandatory.