GBK 80-200

Pressurised electric water heaters

  • Volumes: 80, 100, 120, 150, 200 l.
  • Vertical or horizontal wall mounting (connecting tubes are on the LEFT side).
  • High – quality thermal insulation.
  • Combination of electrical heating and heating from another source via tubular heat exchanger.
  • RN – right side inlet connection or LN – left side inlet connection for the heat exchanger
  • Indirect air heating element.
  • Arbitrary water temperature setting up to 75°C.with a rotating knob
  • Temperature setting options:
    • economical temperature
    • protection against freezing.
  • Thermometer displaying water temperature inside water heater.
  • Indicator of electric heating element operation.
  • Tank made of high quality steel sheet, enamel coated at 850°C.
  • Magnesium anode for additional anti-corrosion protection of tank.
  • Large diameter of heating flange (100 mm) allows simple cleaning and maintenance.

Indirect air heating elements – reliable operation, simple maintenance

Tubular air heating elements are inserted into the heating flange made of special steel and enamelled against corrosion. Compared to conventional immersion heating elements, the advantages of indirect heating element are as follows:

  • the heating elements are not in direct contact with water,
  • the replacement of heating elements is simple as it is not required to empty the water heater before repair,
  • the heating flange incorporates 2 or more heating elements electrically connected in parallel, assuring a higher reliability of operation (if one heating element fails, the water heater still operates),
  • the limestone depositing is reduced and removing the limestone deposit is simpler,
  • the inside surface is completely enamel coated (no blank surfaces, compared to the models with immersion heating elements) therefore Mg anode consumption is reduced and consequently its life span is longer.

Properties

MODEL GBK 80RN / GBK 80LN GBK 100RN / GBK 100LN GBK 120RN / GBK 120LN GBK 150 RN/LN  GBK 200 RN/LN
Volume [l] 80 100 120 150 200
Purpose          
One or more outlets
Vertical wall mounting
Left / right connections for heat exchanger G 3/4 G 3/4 G 3/4 G 3/4 G 3/4
Number of persons - average consumption 3 - 4 4 - 5 5 - 6 6 - 8 8 - 10
Dimensions of Connections          
A (mm) 803 948 1103 1318 1510 
B (mm) 565 715 865 1065 1050
C (mm) 205 200 205 220 430
D [mm] 340 416 416 416 416
Connections to the supply network G 1/2 G 1/2 G 1/2 G 1/2 G 1/2
Net / gross weight / with water [kg] 51/54/131 56/59/156 62/66/182 72/76/222 90/95/295
Technical Characteristics          
Working pressure [bar] 6 6 6 6 6
Enamelled steel tank
Magnesium protective anode
Selection of temperatures up to 75 °C
Protection against freezing
Heating element control lamp
Thermometer
Average thickness of insulation [mm] 40 40 40 40 40
Degree of protection against humidity IP 25 IP 25 IP 25 IP 25 IP 25
Heat Exchanger          
Area of the exchanger [m²] 0,70 0,90 0,90 0,90 0,90
Area of the exchanger [m²] 6 6 6 6 6
Max. input temperature [°C] 85 85 85 85 85
Electrical Characteristics          
Number of heating elements x power  [W] 2 x 1000 2 x 1000 2 x 1000 2 x 1000 2 x 1000
Rated power output [W] 2000 2000 2000 2000 2000
Voltage 230 V ~
Nominal current [A] 8,7 8,7 8,7 8.7 8.7
Functional Characteristics          
Heating time from 15 to 75 °C 3h 05min 3h 55min 4h 35min 5h 45 min 7h 40 min 
Heating time from 15 to 45 °C using heat exchanger 17min 12min 15min 18 min 24 min
Amount of available mixed water at 40 °C [l]¹ 141 187 224 286 387 
Thermal losses [kWh/24 h]² 1,39 1,58 1,77 2.05 2.50
Connection Fittings          
Safety valve or safety group
Reduction valve for pressure > 5 bar
Non-return valve for heat exchanger
Transportation          
Packaging dimensions [mm] 600x600x902 600x600x1047 600x600x1202 600x600x1417 600x600x1609
No. of pieces per truck [120 m³] 288 192 192 192 96
(1) Values are valid for mixing water with temperature of 15 °C from the cold inlet with water at 65 °C from the heater (standard SIST EN 60379:2005).
(2) Measured at 20 °C ambient temperature, and 65 °C water temperature in the heater (standard SIST EN 60379:2005).