GBFU

Pressurised electric water heaters

  • Volumes: 30, 50, 80, 100, 120, 150, 200 l.
  • Vertical or horizontal wall mounting (connecting tubes are on the LEFT side).
  • High - quality thermal insulation.
  • Indirect air heating element.
  • Arbitrary water temperature setting up to 75°C.with a rotating knob
  • Temperature setting options:
      • economical temperature
      • protection against freezing.
  • Thermometer displaying water temperature inside water heater.
  • Indicator of electric heating element operation.
  • Tank made of high quality steel sheet, enamel coated at 850°C.
  • Magnesium anode for additional anti-corrosion protection of tank.
  • Large diameter of heating flange (100 mm) allows simple cleaning and maintenance.

Indirect air heating elements – reliable operation, simple maintenance

Tubular air heating elements are inserted into the heating flange made of special steel and enamelled against corrosion. Compared to conventional immersion heating elements, the advantages of indirect heating element are as follows:

  • the heating elements are not in direct contact with water,
  • the replacement of heating elements is simple as it is not required to empty the water heater before repair,
  • the heating flange incorporates 2 or more heating elements electrically connected in parallel, assuring a higher reliability of operation (if one heating element fails, the water heater still operates),
  • the limestone depositing is reduced and removing the limestone deposit is simpler,
  • the inside surface is completely enamel coated (no blank surfaces, compared to the models with immersion heating elements) therefore Mg anode consumption is reduced and consequently its life span is longer.

Properties

MODEL GBFU 50 N GBFU 80 N GBFU 100 N GBFU 120 N
Volume [l] 50 80 100 120
Purpose        
One or more outlets
Vertical wall mounting
Horizontal wall mounting
Number of persons - average consumption 2 3 - 4 4 - 5 5 - 6
Dimensions of Connections        
A (mm) 583 803 948 1103
B (mm) 365 565 715 865
C (mm) 185 205 200 205
D (mm) 145 345 495 645
Connections to the supply network G 1/2 G 1/2 G 1/2 G 1/2
Net / gross weight / with water  [kg] 24/27/74 30/32/110 34/36/134 41/43/161
Technical Characteristics        
Working pressure [bar] 6 6 6 6
Enamelled steel tank
Magnesium protective anode
Selection of temperatures up to 75 °C
Protection against freezing
Heating element control lamp
Thermometer
Average thickness of insulation [mm] 17 17 17 17
Degree of protection against humidity IP 25 IP 25 IP 25 IP 25
Electrical Characteristics        
Number of heating elements x power  [W] 2x1000 2x1000 2x1000 2x1000
Rated power output [W] 2000 2000 2000 2000
Voltage 230 V ~
Nominal current [A] 8,7 8,7 8,7 8,7
Functional Characteristics        
Heating time from 15 to 75 °C 1h 55min 3h 05 min 3h 55 min 4h 35 min
Amount of available mixed water at 40 °C [l]¹ 96/80 151/130 199/174 238/210
Thermal losses [kWh/ 24 h]² 1,32/1,45 1,85/2,10 2,20/2,45 2,60/2,90
Transportation        
Packaging dimensions [mm ] 480x490x615 480x490x835 480x490x980 480x490x1135
No. of pieces per truck  [120 m³] 640 480 480 320
(1) Values are valid for mixing water with temperature of 15 °C from the cold inlet with water at 65 °C from the heater (standard SIST EN 60379:2005). The data is applicable for vertical or horizontal mounting.
(2) Measured at 20 °C ambient temperature, and 65 °C water temperature in the heater (standard SIST EN 60379:2005).The data is applicable for vertical or horizontal mounting.