Pressurised electric water heaters
- Volumes: 30, 50, 80, 100, 120, 150, 200 l.
- Vertical or horizontal wall mounting (connecting tubes are on the LEFT side).
- High - quality thermal insulation.
- Indirect air heating element.
- Arbitrary water temperature setting up to 75°C.with a rotating knob
- Temperature setting options:
- economical temperature
- protection against freezing.
- Thermometer displaying water temperature inside water heater.
- Indicator of electric heating element operation.
- Tank made of high quality steel sheet, enamel coated at 850°C.
- Magnesium anode for additional anti-corrosion protection of tank.
- Large diameter of heating flange (100 mm) allows simple cleaning and maintenance.
Indirect air heating elements – reliable operation, simple maintenance
Tubular air heating elements are inserted into the heating flange made of special steel and enamelled against corrosion. Compared to conventional immersion heating elements, the advantages of indirect heating element are as follows:
- the heating elements are not in direct contact with water,
- the replacement of heating elements is simple as it is not required to empty the water heater before repair,
- the heating flange incorporates 2 or more heating elements electrically connected in parallel, assuring a higher reliability of operation (if one heating element fails, the water heater still operates),
- the limestone depositing is reduced and removing the limestone deposit is simpler,
- the inside surface is completely enamel coated (no blank surfaces, compared to the models with immersion heating elements) therefore Mg anode consumption is reduced and consequently its life span is longer.
Properties
| Volume [l] |
50 |
80 |
100 |
120 |
| Purpose |
|
|
|
|
| One or more outlets |
• |
• |
• |
• |
| Vertical wall mounting |
• |
• |
• |
• |
| Horizontal wall mounting |
• |
• |
• |
• |
| Number of persons - average consumption |
2 |
3 - 4 |
4 - 5 |
5 - 6 |
| Dimensions of Connections |
|
|
|
|
| A (mm) |
583 |
803 |
948 |
1103 |
| B (mm) |
365 |
565 |
715 |
865 |
| C (mm) |
185 |
205 |
200 |
205 |
| D (mm) |
145 |
345 |
495 |
645 |
| Connections to the supply network |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
| Net / gross weight / with water [kg] |
24/27/74 |
30/32/110 |
34/36/134 |
41/43/161 |
| Technical Characteristics |
|
|
|
|
| Working pressure [bar] |
6 |
6 |
6 |
6 |
| Enamelled steel tank |
• |
• |
• |
• |
| Magnesium protective anode |
• |
• |
• |
• |
| Selection of temperatures up to 75 °C |
• |
• |
• |
• |
| Protection against freezing |
• |
• |
• |
• |
| Heating element control lamp |
• |
• |
• |
• |
| Thermometer |
• |
• |
• |
• |
| Average thickness of insulation [mm] |
17 |
17 |
17 |
17 |
| Degree of protection against humidity |
IP 25 |
IP 25 |
IP 25 |
IP 25 |
| Electrical Characteristics |
|
|
|
|
| Number of heating elements x power [W] |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
| Rated power output [W] |
2000 |
2000 |
2000 |
2000 |
| Voltage 230 V ~ |
• |
• |
• |
• |
| Nominal current [A] |
8,7 |
8,7 |
8,7 |
8,7 |
| Functional Characteristics |
|
|
|
|
| Heating time from 15 to 75 °C |
1h 55min |
3h 05 min |
3h 55 min |
4h 35 min |
| Amount of available mixed water at 40 °C [l]¹ |
96/80 |
151/130 |
199/174 |
238/210 |
| Thermal losses [kWh/ 24 h]² |
1,32/1,45 |
1,85/2,10 |
2,20/2,45 |
2,60/2,90 |
| Transportation |
|
|
|
|
| Packaging dimensions [mm ] |
480x490x615 |
480x490x835 |
480x490x980 |
480x490x1135 |
| No. of pieces per truck [120 m³] |
640 |
480 |
480 |
320 |
(1) Values are valid for mixing water with temperature of 15 °C from the cold inlet with water at 65 °C from the heater (standard SIST EN 60379:2005). The data is applicable for vertical or horizontal mounting.
(2) Measured at 20 °C ambient temperature, and 65 °C water temperature in the heater (standard SIST EN 60379:2005).The data is applicable for vertical or horizontal mounting.
|