Pressurised electric water heaters
GB electric water heaters are the result of the application of a wealth of experience utilised in conjunction with application of the most modern technical solutions. The original solution of the heating element guarantees improved applicability and reliability of operation, also ensuring that the GB heater requires an absolute minimum of maintenance. Due to its universal design, the GB heater can be wall-mounted vertically or fixed horizontally on the floor. For better energy performance is available model with EcoSmart function GB SM.
ADVANTAGES:
- Supply of several outlets
- Vertical wall mounting
- High-quality insulation for lower heat losses
- Heating flange with tubular air heating elements
- Electronic control unit
- Heater on/off and temperature adjustment key
- Temperature adjustable from 10 °C to 75 °C
- 7 LED temperature indicator
- Dry fire protection
- Overheating protection
- Anti-Legionella function
- Heating element operation indicator
- Error/fault indicator
- Working pressure 6 to 9 bar
- Anti-corrosion tank protection with enamel and a magnesium anode
- Available volumes/capacities: 30 l, 50 l, 80 l, 100 l, 120 l, 150 l, 200 l
- Simple installation and maintenance GB SM ADDITIONAL :
- Available volumes/capacities: 30 l, 50 l, 80 l, 100 l, 120 l and 150 l
- EcoSmart function on/off key
- Water consumption monitoring: Eco Smart function
- Data remains stored even in case of a power supply failure
- Smart operation indicator
|
|
|
Properties
GB OR
Declared load profile |
S |
M |
M |
L |
L |
XL |
XL |
Energy efficiency class (1) |
C |
C |
C |
C |
C |
C |
D |
Energy efficiency ƞwh (1) (%) |
32,9 |
36,3 |
36,1 |
37,4 |
37,1 |
38,1 |
35,2 |
AEC annual electricity consumption (1) (kWh) |
560 |
1414 |
1421 |
2738 |
2763 |
4395 |
4756 |
Daily electricity consumption Qelec (2) (kWh) |
2,686 |
6,610 |
6,650 |
12,710 |
12,860 |
20,295 |
22,430 |
Thermostat temperature settings |
"eco" |
"eco" |
"eco" |
"eco" |
"eco" |
"eco" |
"eco" |
Specific precautions (assembly, install, maintain) |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
Value of smart |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Storage volume V (l) |
30,4 |
47,0 |
76,1 |
96,1 |
116,4 |
145,5 |
194,9 |
Mixed water at 40°C V40 (2) (l) |
66 |
116 |
137 |
172 |
213 |
273 |
|
PURPOSE |
|
|
|
|
|
|
|
One or more outlets |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
* Vertical wall mounting |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Horizontal floor mounting |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
DIMENSIONS OF CONNECTIONS |
|
|
|
|
|
|
|
Height (mm) |
535 |
590 |
810 |
955 |
1110 |
1325 |
1517 |
Diameter (mm) |
454 |
500 |
500 |
500 |
500 |
500 |
500 |
Depth (mm) |
461 |
507 |
507 |
507 |
507 |
507 |
507 |
Connections to the supply network |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
Net/gross weight/with water (kg) |
20/22/50 |
27/30/77 |
33/36/113 |
38/41/138 |
43/47/163 |
49/54/199 |
65/69/265 |
TECHNICAL CHARACTERISTICS |
|
|
|
|
|
|
|
Working pressure (Mpa(bar)) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
Enamelled steel tank |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Protective magnesium anode |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Electronic control unit |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
On/Off key |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Temperature range adjustment up to 75 °C |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
LED thermometer |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Overheating protection |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Dry fire protection |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Setting to “freeze prevention” |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of heating element operation |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of thermostat failure |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of over heating |
+ |
+ |
+ |
+ |
+ |
+ |
+ |
Degree of protection |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
ELECTRICAL CONNECTIONS |
|
|
|
|
|
|
|
Number of heating elements x power (W) |
3x700 |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
2000 |
Rated power output (W) |
2100 |
2000 |
2000 |
2000 |
2000 |
2000 |
+ |
Voltage 230 V~ |
+ |
+ |
+ |
+ |
+ |
+ |
|
Nominal current (A) |
9,1 |
8,7 |
8,7 |
8,7 |
8,7 |
8,7 |
8,7 |
FUNCTIONAL CHARACTERISTICS |
|
|
|
|
|
|
|
Thermal losses at 65°C (3) (kWh/24) |
0,9 |
1 |
1,2 |
1,33 |
1,55 |
1,64 |
2,1 |
Heating time from 10 to 65°C |
0h59min |
1h38min |
2h7min |
3h16min |
3h55min |
4h54min |
6h32min |
TRASNPORTATION DATA |
|
|
|
|
|
|
|
Packaging dimensions (mm) |
480x490x595 |
600x600x682 |
600x600x905 |
600x600x1050 |
600x600x1205 |
600x600x1420 |
600x600x1615 |
GB SM
Declared load profile |
S |
M |
M |
L |
L |
XL |
Energy efficiency class (1) |
B |
B |
B |
C |
C |
C |
Energy efficiency ƞwh (1) (%) |
37,7 |
40,5 |
40,2 |
41,4 |
40,4 |
39,6 |
AEC annual electricity consumption (1) (kWh) |
489 |
1267 |
1277 |
2472 |
2532 |
4224 |
Daily electricity consumption Qelec (2) (kWh) |
2,690 |
6,698 |
6,788 |
12,950 |
13,433 |
20,700 |
Thermostat temperature settings |
"eco" |
"eco" |
"eco" |
"eco" |
"eco" |
"eco" |
Specific precautions (assembly, install, maintain) |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
Value of smart |
1 |
1 |
1 |
1 |
1 |
1 |
Weekly electricity consumption with smart control Qelec, week, smart(kWh) |
12,941 |
23,547 |
24,814 |
49,140 |
49,540 |
85,202 |
Weekly electricity consumption without smart control Qelec, week (kWh) |
15,355 |
27,450 |
28,999 |
57,132 |
57,899 |
91,701 |
Storage volume V (l) |
30,4 |
47,0 |
76,1 |
96,1 |
116,4 |
145,5 |
Mixed water at 40°C V40 (2) (l) |
|
66 |
116 |
137 |
172 |
213 |
PURPOSE |
|
|
|
|
|
|
One or more outlets |
+ |
+ |
+ |
+ |
+ |
+ |
* Vertical wall mounting |
+ |
+ |
+ |
+ |
+ |
+ |
Horizontal floor mounting |
+ |
+ |
+ |
+ |
+ |
+ |
DIMENSIONS OF CONNECTIONS |
|
|
|
|
|
|
Height (mm) |
535 |
590 |
810 |
955 |
1110 |
1325 |
Diameter (mm) |
454 |
500 |
500 |
500 |
500 |
500 |
Depth (mm) |
461 |
507 |
507 |
507 |
507 |
507 |
Connections to the supply network |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
Net/gross weight/with water (kg) |
20/22/50 |
27/30/77 |
33/36/113 |
38/41/138 |
43/47/163 |
49/54/199 |
TECHNICAL CHARACTERISTICS |
|
|
|
|
|
|
Working pressure (Mpa(bar)) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
Enamelled steel tank |
+ |
+ |
+ |
+ |
+ |
+ |
Protective magnesium anode |
+ |
+ |
+ |
+ |
+ |
+ |
Electronic control unit |
+ |
+ |
+ |
+ |
+ |
+ |
On/Off key |
+ |
+ |
+ |
+ |
+ |
+ |
Temperature range adjustment up to 75 °C |
+ |
+ |
+ |
+ |
+ |
+ |
LED thermometer |
+ |
+ |
+ |
+ |
+ |
+ |
Overheating protection |
+ |
+ |
+ |
+ |
+ |
+ |
Dry fire protection |
+ |
+ |
+ |
+ |
+ |
+ |
Setting to “freeze prevention” |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of heating element operation |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of thermostat failure |
+ |
+ |
+ |
+ |
+ |
+ |
Indication of over heating |
+ |
+ |
+ |
+ |
+ |
+ |
Degree of protection |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
IP 24 |
ELECTRICAL CONNECTIONS |
|
|
|
|
|
|
Number of heating elements x power (W) |
3x700 |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
Rated power output (W) |
2100 |
2000 |
2000 |
2000 |
2000 |
2000 |
Voltage 230 V~ |
+ |
+ |
+ |
+ |
+ |
+ |
Nominal current (A) |
9,1 |
8,7 |
8,7 |
8,7 |
8,7 |
8,7 |
FUNCTIONAL CHARACTERISTICS |
|
|
|
|
|
|
Thermal losses at 65°C (3) (kWh/24) |
0,9 |
1 |
1,2 |
1,33 |
1,55 |
1,64 |
Heating time from 10 to 65°C |
0h59min |
1h38min |
2h7min |
3h16min |
3h55min |
4h54min |
TRASNPORTATION DATA |
|
|
|
|
|
|
Packaging dimensions (mm) |
480x490x595 |
600x600x682 |
600x600x905 |
600x600x1050 |
600x600x1205 |
600x600x1420 |
(1) EU Regulation 812/2013; EN 50440
(2) EN 50440
(3) Measured at 20°C ambient temperatur e and 65°C water temperatur e in the heater (SIST EN 60379:2005 standar d).
* information on water heating ener gy efficiency and annual electricity consumption r elate to enabled smart contr ol settings only and vertical wall mounting position
A (mm) |
535 |
590 |
810 |
955 |
1110 |
1325 |
1517 |
B (mm) |
305 |
415 |
615 |
765 |
915 |
1115 |
1100 |
C (mm) |
245 |
190 |
210 |
205 |
210 |
225 |
430 |
D (mm) |
- |
- |
- |
- |
- |
- |
800 |
E (mm) |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
F (mm) |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
G (mm) |
350 |
350 |
350 |
350 |
350 |
350 |
350 |
|