Hot water storage tanks
The GV heater is designed for upright floor installation. The top performance heat exchanger has a large heating surface and can be connected to various central heating boilers: gas boiler, fuel boiler, and district heating system. Installation under a wall mounted gas heater is especially recommended.
ADVANTAGES:
- Volumes: 100, 120, 150, 200 l.
- Hot water storage tank with tubular heat exchanger (rear side connections).
- Floor upright version.
- Compact size, particularly suitable for installation under the wall version gas boiler.
- Tank made of high quality steel sheet, enamel coated at 850°C.
- Mg anode for additional anticorrosion protection of the tank.
- Bimetal thermometer displaying water temperature in heater.
- High quality insulation - lower heat loss.
|
|
|
Properties
Standing loss S (2) (W) |
65,8 |
73,8 |
85,4 |
104,2 |
Storage volume (l) |
92,5 |
112,9 |
141,5 |
188,9 |
DIMENSIONS OF CONNECTIONS |
|
|
|
|
Height (mm) |
948 |
1103 |
1318 |
1510 |
Diameter (mm) |
500 |
500 |
500 |
500 |
Depth (mm) |
507 |
507 |
507 |
507 |
Connections to the supply network |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
Connections to the heat exchanger |
G 3/4 |
G 3/4 |
G 3/4 |
G 3/4 |
Net/gross weight/with water (kg) |
54/57/154 |
60/64/180 |
70/74/220 |
88/93/288 |
TECHNICAL CHARACTERISTICS |
|
|
|
|
Working pressure (MPa(bar)) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
0,6(6)/0,9(9) |
Enamelled steel tank |
+ |
+ |
+ |
+ |
Protective magnesium anode |
+ |
+ |
+ |
+ |
Thermometer |
+ |
+ |
+ |
+ |
Average thickness of insulation (mm) |
40 |
40 |
40 |
25 |
Degree of protection |
IP 23 |
IP 23 |
IP 23 |
IP 23 |
HEAT EXCHANGER |
|
|
|
|
Heat exchanger area (m2) |
0,9 |
0,9 |
0,9 |
0,9 |
Volume (l) |
4,2 |
4,2 |
4,2 |
4,2 |
Heating power (3) (kW) |
17,6 |
17,6 |
17,6 |
17,6 |
Max. pressure of the heating medium (MPa(bar)) |
0,6(6) |
0,6(6) |
0,6(6) |
0,6(6) |
Max. input temperature (°C) |
85 |
85 |
85 |
85 |
FUNCTIONAL CHARACTERISTICS |
|
|
|
|
Heating time from 10 to 45°C with hear exchanger |
12min |
15min |
18min |
24min |
Thermal losses (2) (kWh/24h) |
1,58 |
1,77 |
2,05 |
2,5 |
TRANSPORTATION DATA |
|
|
|
|
Packaging dimensions (mm) |
600x600x1047 |
600x600x1202 |
600x600x1417 |
600x600x1609 |
(1) EU Regulation 812/2013; EN 50440
(2) Tested according to EN 12897:2006 or EN 60379:2005
(3) Heating of sanitary water fr om 10°C to 45°C with temperatur e of inlet heating medium at 70°C and heating medium flow at 30 00l/h
A (mm) |
955 |
1100 |
1325 |
1520 |
E (mm) |
100 |
100 |
100 |
100 |
H (mm) |
416 |
416 |
416 |
416 |
HV (mm) |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
TV (mm) |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
CV (mm) |
G 1/2 |
G 1/2 |
G 1/2 |
G 1/2 |
VM (mm) |
G 3/4 |
G 3/4 |
G 3/4 |
G 3/4 |
IM (mm) |
G 3/4 |
G 3/4 |
G 3/4 |
G 3/4 |
|