TC Z and TC ZNT - Wall mounted heat pump water heaters air ducted

Aiming for maximum energy savings, Gorenje’s new medium tank volume air-to-water heat pump is the product of longstanding experience in the design and manufacture of heat pumps and electric water heaters. The highly energy efficient 80/100/120 litre air-to-water heat pump has been designed as a perfect replacement for the electric water heater. The conventional medium tank volume has been augmented with a heat pump generator, which delivers superior energy performance. The air-to-water heat pump design with air ducts enables the selection of inlet and outlet points for the air, which allows its use in various parts of the home (kitchen, bathroom, sunrooms, etc.).

ADVANTAGES:

  • Volume: 80, 100 and 120 liters.
  • Operating range from+7°C to+35°C.
  • Low temperature version: Operating range from -7°C to+35°C.
  • Rotation compressor.
  • Wrap around condenser.
  • Air ducted version.
  • Legionella Control Programme.
  • Possibility of independent fan operation.
  • Indirect air heating elements.
  • Electronic controller with LCD touch display.
  • Tank made of high quality steel sheet, enamel coated at 850°C.
  • Magnesium anode for additional anti-corrosion protection of the tank.
  • Eco friendly refrigerant R134a.
MODEL TC80Z TC80ZNT TC100Z TC100ZNT TC120Z TC120ZNT
Declared load profile M M M M M M
Energy efficiency class (1) A A A A A A
Energy efficiency ƞwh (1) 111,3 % 111,3 % 110,7 % 110,7 % 111,8 % 111,8 %
AEC annual electricity consumption_ACC (1) 461 kWh 461 kWh 464 kWh 464 kWh 459 kWh 459 kWh
Daily electricity consumption Qelec_ACC (2) 2,205 kWh 2,205 kWh 2,225 kWh 2,225 kWh 2,240 kWh 2,240kWh
Thermostat temperature settings 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Sound power level LWA, indoors /Sound Pressure on 1m (3) 51/39,5 dB(A) 51/39,5 dB(A) 51/39,5 dB(A) 51/39,5 dB(A) 51/39,5 dB(A) 51/39,5 dB(A)
Specific precautions (assembly, install, maintain) When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory When connected as pressurised, use of safety valve is mandatory
Value of smart 0 0 0 0 0 0
Storage volume V 78,2 l 78,2 l 97,9 l 97,9 l 117,6 l 117,6 l
Mixed water at 40°C V40 (2) 90 l 90 l 130 l 130 l 142 l 142 l
TECHNICAL CHARACTERISTICS            
Heating up Period A15/W10-55 * 4:40 4:40 5:40 5:40 6:40 6:40
Heating up Period A7/W10-55 ** 5:20 5:20 6:50 6:50 8:41 8:41
Energy consuption by chosen cyclus A15/W10-55* 2,04 kWh 2,04 kWh 2,05 kWh 2,05 kWh 2,08 kWh 2,08 kWh
Energy consuption by chosen cyclus A7/W10-55** 2,45 kWh 2,45 kWh 2,35 kWh 2,35 kWh 2,51 kWh 2,51 kWh
COPDHW (A15/W10-55) EN 16147* 3,10 3,10 3,10 3,10 3,10 3,10
COPDHW (A7/W10-55) EN 16147** 2,65 2,65 2,63 2,63 2,61 2,61
Standby power input according to EN16147 19 W 19 W 20 W 20 W 27 W 27 W
Refrigiant R134a R134a R134a R134a R134a R134a
Quantty of refrigiant 490 g 540 g 490 g 540 g 490 g 540 g
Working range - air temparature 7/35 °C -7/+35 °C 7/35 °C -7/+35 °C 7/35 °C -7/+35 °C
Working Air Flow 100-230 m3/h 100-230 m3/h 100-230 m3/h 100-230 m3/h 100-230 m3/h 100-230 m3/h
Pressure Drop by 150 m3/h (60%/80%) 70 (90) Pa 70 (90) Pa 70 (90) Pa 70 (90) Pa 70 (90) Pa 70 (90) Pa
ELECTRICAL SPECIFICATIONS            
Nominal electrical power -compressor 250 W 250 W 250 W 250 W 250 W 250 W
Maximum power consumption 2350 W 2350 W 2350 W 2350 W 2350 W 2350 W
Number of electric heaters x power 2 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W 2 x 1000 W
Voltage/Frequecy 230/50 V/Hz 230/50 V/Hz 230/50 V/Hz 230/50 V/Hz 230/50 V/Hz 230/50 V/Hz
Electric protection 16 A 16 A 16 A 16 A 16 A 16 A
Protection IP24 IP24 IP24 IP24 IP24  
STORAGE TANK            
Enamelled steel / Protection Mg anode +/+ +/+ +/+ +/+ +/+  
Working pressure (Mpa(bar)) 0,6(6)/0,9(9) 0,6(6)/0,9(9) 0,6(6)/0,9(9) 0,6(6)/0,9(9) 0,6(6)/0,9(9) 0,6(6)/0,9(9)
MAX TEMPERATURE            
Hot water tank heat pump 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Hot water tank electric heater 75 °C 75 °C 75 °C 75 °C 75 °C 75 °C
CONNECTION DIMENSIONS            
Height 1197 mm 1197 mm 1342 mm 1342 mm 1497 mm 1497  mm
Width 506 mm 506 mm 506 mm 506 mm 506 mm 506  mm
Depth 506 mm 506 mm 506 mm 506 mm 506 mm 506  mm
Connections to the watter supply network G1/2 G1/2 G1/2 G1/2 G1/2  
Dimensions of air connections (mm/m) Ø125 (150x70)/10 Ø125 (150x70)/10 Ø125 (150x70)/10 Ø125 (150x70)/10 Ø125 (150x70)/10 Ø125 (150x70)/10
Neto/with Watter 58/138 kg 58/138 kg 62/162 kg 62/162 kg 68/188 kg 68/188 kg
TRANSPORT DATA            
Packaging dimensions 575x600x1440 mm 575x600x1440 mm 575x600x1555 mm 575x600x1555 mm 575x600x1680 mm 575x600x1680 mm
(1) EU Regulation 812/2013; EN 16147:2010, A verage Climate Conditions (ACC)
(2) EN 16147:2010
(3) EN 12102:2013
(*) by air inlet temparatur e of 15 °C, 74% humidity and 10 °C watter on beginning heated u p till 55 °C r egarding to EN16147
(**) by air inlet temparatur e of 7 °C, 89% humidity and 10 °C watter on beginning heated up till 55 °C r egarding to EN16147