TC SPLIT - Heat pump water heaters
Besides compact water heater heat pumps, we have expanded our product range with a separate aggregate - outdoor unit models air-to-water heat pump water heaters. The heat pump outdoor unit can be installed at both wall and floor and can be easily connected with an indoor wall hanging or floor standing storage tank by flare connections on refrigerant pipes. It offers easier integration in places where the space is at premium. TC SPLIT was developed to meet the needs of families who want to protect the environment and still want to enjoy comfort. Equipped with modern electronic controller with back light LCD display offers features that make your life easier: time programming, quick heating, several days absence, display of available hot water.
ADVANTAGES:
- Indoor unit: wall hanging (120l and 150l) or floor standing (200l and 300l) hot water storage tank with integrated LCD display electronic control unit.
- Outdoor unit: heat pump unit.
- Operating range from -7 °C to + 35 °C.
- Storage tank made from high-quality steel sheet, enameled at 850 °C.
- Magnesium anode for additional anti-corrosion tank protection.
- Auxiliary electric heating elements inserted into the protective pipe of the heating flange are not in direct contact with the water that provides excellent protection against corrosion and reduces the accumulation of limescale.
- Heat pump condenser wrapped around the tank.
- Environmentally friendly refrigerant R134a.
- Electronic controller with LCD touch screen.
FUNCTIONS:
- Turbo heating program
- Heating to a higher temperature 75 °C.
- Time modes of operation
- Activation and setting the HOLIDAY program
- Anti-Legionella program
- Connection to the photovoltaic system
SETTINGS:
- On / Off
- Time and day of the week
- Temperature of water
- Days of absence
SIGNALIZATION:
- The amount of available hot water
- Operation of electric heating element
- Operation of the compressor
- Operation of the fan
- Activation of the anti-Legionella program
- Defrost activation
- Operation with energy from the PV system
- Back-up mode of operation
- Error indication - code display
CERTIFICATES: SIQ, CE, EMC
DIMENSIONS:
|
|
|
TECHNICAL DATA:
Declared load profile |
M |
L |
Energy efficiency class (1) |
A |
A |
Energy efficiency ƞwh (1) |
101,9 % |
111,2 % |
AEC annual electricity consumption_ACC (1) |
504 kWh |
921 kWh |
Daily electricity consumption Qelec_ACC (2) |
2,397 kWh |
4,302 kWh |
Thermostat temperature settings |
55 °C |
55 °C |
Value of smart |
0 |
0 |
Storage volume V |
117,6 l |
146,6 l |
Mixed water at 40°C V40 (2) |
152 l |
199 l |
TECHNICAL CHARACTERISTICS |
|
|
COPDHW (A15/W10-55) EN 16147* |
2,44 |
2,71 |
Working range - air temparature |
-7 to +35 °C |
-7 to +35 °C |
Heating up Period A7/W10-55* |
4:10 h:min |
5:13 h:min |
Average thickness of insulation |
50 mm |
50 mm |
Standby power input |
19 W |
20 W |
Connections to the watter supply network |
G1/2 |
G1/2 |
Netto/gross/with watter |
51/54/169 kg |
59/62/206 kg |
OUTDOOR UNIT |
|
|
Dimensions of refrigerant connections liquid- gas |
1/4" - 3/8" |
1/4" - 3/8" |
Net weight (empty) |
29 kg |
29 kg |
Working Air Flow |
1800 m3/h |
1800 m3/h |
Sound power level LWA, outdoors /Sound Pressure on 1m (3) |
56/46 dB(A) |
56/46 dB(A) |
Refrigerant** |
R134a (GWP 1430) |
R134a (GWP 1430) |
Quantty of refrigiant |
1,000 kg |
1,000 kg |
Design pressure of the circuit (low) |
1,0 (Mpa) 10,0 (bar) |
1,0 (Mpa) 10,0 (bar) |
Design pressure of the circuit (high) |
2,6 (Mpa) 26,0 (bar) |
2,6 (Mpa) 26,0 (bar) |
Degree of protection |
IP24 |
IP24 |
Gas connection maximum lenght |
8 m |
8 m |
Gas connection maximum drop |
3 m |
3 m |
ACCESSORIES |
|
|
Shelded probe connection cable between units 10m |
+ |
+ |
TRANSPORTATION DATA |
|
|
Indoor unit (HxDxW) |
1340x600x575 mm |
1555x600x575 mm |
Outdoor unit (HxDxW) |
610x350x815 mm |
610x350x815 mm |
Declared load profile |
L |
L |
Energy efficiency class (1) |
A |
A |
Energy efficiency ƞwh (1) |
108,7 % |
106,6 % |
AEC annual electricity consumption_ACC (1) |
942 kWh |
961 kWh |
Daily electricity consumption Qelec_ACC (2) |
4,449 kWh |
4,539 kWh |
Thermostat temperature settings |
55 °C |
55 °C |
Value of smart |
0 |
0 |
Storage volume V |
201,6 l |
194 l |
Mixed water at 40°C V40 (2) |
259 l |
243 l |
TECHNICAL CHARACTERISTICS |
|
|
COPDHW (A15/W10-55) EN 16147* |
2,62 |
2,57 |
Working range - air temparature |
-7 to +35 °C |
-7 to +35 °C |
Heating up Period A7/W10-55* |
6:15 h:min |
6:08 h:min |
Average thickness of insulation |
67 mm |
67 mm |
Standby power input |
29 W |
30 W |
Connections to the watter supply network |
G1 |
G1 |
Netto/gross/with watter |
77/89/279 kg |
100/112/294 kg |
OUTDOOR UNIT |
|
|
Dimensions of refrigerant connections liquid- gas |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Net weight (empty) |
29 kg |
29 kg |
Working Air Flow |
1800 m3/h |
1800 m3/h |
Sound power level LWA, outdoors /Sound Pressure on 1m (3) |
56/46 dB(A) |
56/46 dB(A) |
Refrigerant** |
R134a (GWP 1430) |
R134a (GWP 1430) |
Quantty of refrigiant |
1,150 kg |
1,150 kg |
Design pressure of the circuit (low) |
1,0 (Mpa) 10,0 (bar) |
1,0 (Mpa) 10,0 (bar) |
Design pressure of the circuit (high) |
2,6 (Mpa) 26,0 (bar) |
2,6 (Mpa) 26,0 (bar) |
Degree of protection |
IP24 |
IP24 |
Gas connection maximum lenght |
8 m |
8 m |
Gas connection maximum drop |
3 m |
3 m |
ACCESSORIES |
|
|
Shelded probe connection cable between units 10m |
+ |
+ |
TRANSPORTATION DATA |
|
|
Indoor unit (HxDxW) |
1500x800x800 mm |
1500x800x800 mm |
Outdoor unit (HxDxW) |
610x350x815 mm |
610x350x815 mm |
Declared load profile |
XL |
XL |
Energy efficiency class (1) |
A |
A |
Energy efficiency ƞwh (1) |
116,1 % |
109,9 % |
AEC annual electricity consumption_ACC (1) |
1443 kWh |
1525 kWh |
Daily electricity consumption Qelec_ACC (2) |
6,715 kWh |
7,093 kWh |
Thermostat temperature settings |
55 °C |
55 °C |
Value of smart |
0 |
0 |
Storage volume V |
295 l |
276 l |
Mixed water at 40°C V40 (2) |
395 l |
370 l |
TECHNICAL CHARACTERISTICS |
|
|
COPDHW (A15/W10-55) EN 16147* |
2,84 |
2,69 |
Working range - air temparature |
-7 to +35 °C |
-7 to +35 °C |
Heating up Period A7/W10-55* |
10:06 h:min |
9:48 h:min |
Average thickness of insulation |
67 mm |
67 mm |
Standby power input |
26 W |
27 W |
Connections to the watter supply network |
G1 |
G1 |
Netto/gross/with watter |
96/108/391 kg |
138/150/414 kg |
OUTDOOR UNIT |
|
|
Dimensions of refrigerant connections liquid- gas |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Net weight (empty) |
29 kg |
29 kg |
Working Air Flow |
1800 m3/h |
1800 m3/h |
Sound power level LWA, outdoors /Sound Pressure on 1m (3) |
56/46 dB(A) |
56/46 dB(A) |
Refrigerant** |
R134a (GWP 1430) |
R134a (GWP 1430) |
Quantty of refrigiant |
1,150 kg |
1,150 kg |
Design pressure of the circuit (low) |
1,0 (Mpa) 10,0 (bar) |
1,0 (Mpa) 10,0 (bar) |
Design pressure of the circuit (high) |
2,6 (Mpa) 26,0 (bar) |
2,6 (Mpa) 26,0 (bar) |
Degree of protection |
IP24 |
IP24 |
Gas connection maximum lenght |
8 m |
8 m |
Gas connection maximum drop |
3 m |
3 m |
ACCESSORIES |
|
|
Shelded probe connection cable between units 10m |
+ |
+ |
TRANSPORTATION DATA |
|
|
Indoor unit (HxDxW) |
1890x800x800 mm |
1890x800x800 mm |
Outdoor unit (HxDxW) |
610x350x815 mm |
610x350x815 mm |
Declared load profile |
XL |
XL |
Energy efficiency class (1) |
A |
A |
Energy efficiency ƞwh (1) |
109,9 % |
112,4 % |
AEC annual electricity consumption_ACC (1) |
1525 kWh |
1491 kWh |
Daily electricity consumption Qelec_ACC (2) |
7,093 kWh |
6,938 kWh |
Thermostat temperature settings |
55 °C |
55 °C |
Value of smart |
0 |
0 |
Storage volume V |
276 l |
283 l |
Mixed water at 40°C V40 (2) |
370 l |
381 l |
TECHNICAL CHARACTERISTICS |
|
|
COPDHW (A15/W10-55) EN 16147* |
2,69 |
2,75 |
Working range - air temparature |
-7 to +35 °C |
-7 to +35 °C |
Heating up Period A7/W10-55* |
9:48 h:min |
9:59 h:min |
Average thickness of insulation |
67 mm |
67 mm |
Standby power input |
27 W |
27 W |
Connections to the watter supply network |
G1 |
G1 |
Netto/gross/with watter |
139/151/415 kg |
122/134/405 kg |
OUTDOOR UNIT |
|
|
Dimensions of refrigerant connections liquid- gas |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Ø6,35 - Ø9,52(1/4”- 3/8”) |
Net weight (empty) |
29 kg |
29 kg |
Working Air Flow |
1800 m3/h |
1800 m3/h |
Sound power level LWA, outdoors /Sound Pressure on 1m (3) |
56/46 dB(A) |
56/46 dB(A) |
Refrigerant** |
R134a (GWP 1430) |
R134a (GWP 1430) |
Quantty of refrigiant |
1,150 kg |
1,150 kg |
Design pressure of the circuit (low) |
1,0 (Mpa) 10,0 (bar) |
1,0 (Mpa) 10,0 (bar) |
Design pressure of the circuit (high) |
2,6 (Mpa) 26,0 (bar) |
2,6 (Mpa) 26,0 (bar) |
Degree of protection |
IP24 |
IP24 |
Gas connection maximum lenght |
8 m |
8 m |
Gas connection maximum drop |
3 m |
3 m |
ACCESSORIES |
|
|
Shelded probe connection cable between units 10m |
+ |
+ |
TRANSPORTATION DATA |
|
|
Indoor unit (HxDxW) |
1890x800x800 mm |
1890x800x800 mm |
Outdoor unit (HxDxW) |
610x350x815 mm |
610x350x815 mm |
(1) EU Regulation 812/2013; EN 16147:2010, A verage Climate Conditions (ACC)
(2) EN 16147:2010
(3) EN 12102:2013
(*) by air inlet temparatur e of 7 °C, 89% humidity and 10 °C watter on beginning heated up till 55 °C r egarding to EN16147
(**) this product contains fluorinated greenhouse gases. Hermetically sealed
|
|