TC SPLIT - Heat pump water heaters

Besides compact water heater heat pumps, we have expanded our product range with a separate aggregate - outdoor unit models air-to-water heat pump water heaters. The heat pump outdoor unit can be installed at both wall and floor and can be easily connected with an indoor wall hanging or floor standing storage tank by flare connections on refrigerant pipes. It offers easier integration in places where the space is at premium.  TC SPLIT was developed to meet the needs of families who want to protect the environment and still want to enjoy comfort. Equipped with modern electronic controller with back light LCD display offers features that make your life easier: time programming, quick heating, several days absence, display of available hot water.

ADVANTAGES:

  • Indoor unit: wall hanging (120l and 150l) or floor standing (200l and 300l) hot water storage tank with integrated LCD display electronic control unit.
  • Outdoor unit: heat pump unit.
  • Operating range from -7 °C to + 35 °C.
  • Storage tank made from high-quality steel sheet, enameled at 850 °C.
  • Magnesium anode for additional anti-corrosion tank protection.
  • Auxiliary electric heating elements inserted into the protective pipe of the heating flange are not in direct contact with the water that provides excellent protection against corrosion and reduces the accumulation of limescale.
  • Heat pump condenser wrapped around the tank.
  • Environmentally friendly refrigerant R134a.
  • Electronic controller with LCD touch screen.

FUNCTIONS:

  • Turbo heating program
  • Heating to a higher temperature 75 °C.
  • Time modes of operation
  • Activation and setting the HOLIDAY program
  • Anti-Legionella program
  • Connection to the photovoltaic system

SETTINGS:

  • On / Off
  • Time and day of the week
  • Temperature of water
  • Days of absence

SIGNALIZATION:

  • The amount of available hot water
  • Operation of electric heating element
  • Operation of the compressor
  • Operation of the fan
  • Activation of the anti-Legionella program
  • Defrost activation
  • Operation with energy from the PV system
  • Back-up mode of operation
  • Error indication - code display

CERTIFICATES: SIQ, CE, EMC

DIMENSIONS:

TECHNICAL DATA:
MODEL TC 120 SPLIT TC 150 SPLIT
Declared load profile M L
Energy efficiency class (1) A A
Energy efficiency ƞwh (1) 101,9 % 111,2 %
AEC annual electricity consumption_ACC (1) 504 kWh 921 kWh
Daily electricity consumption Qelec_ACC (2) 2,397 kWh 4,302 kWh
Thermostat temperature settings 55 °C 55 °C
Value of smart 0 0
Storage volume V 117,6 l 146,6 l
Mixed water at 40°C V40 (2) 152 l 199 l
TECHNICAL CHARACTERISTICS    
COPDHW (A15/W10-55) EN 16147* 2,44 2,71
Working range - air temparature -7 to +35 °C -7 to +35 °C
Heating up Period A7/W10-55* 4:10 h:min 5:13 h:min
Average thickness of insulation 50 mm 50 mm
Standby power input 19 W 20 W
Connections to the watter supply network G1/2 G1/2
Netto/gross/with watter 51/54/169 kg 59/62/206 kg
OUTDOOR UNIT    
Dimensions of refrigerant connections liquid- gas 1/4" - 3/8" 1/4" - 3/8"
Net weight (empty) 29 kg 29 kg
Working Air Flow 1800 m3/h 1800 m3/h
Sound power level LWA, outdoors /Sound Pressure on 1m (3) 56/46 dB(A) 56/46 dB(A)
Refrigerant** R134a (GWP 1430) R134a (GWP 1430)
Quantty of refrigiant 1,000 kg 1,000 kg
Design pressure of the circuit (low) 1,0 (Mpa) 10,0 (bar) 1,0 (Mpa) 10,0 (bar) 
Design pressure of the circuit (high) 2,6 (Mpa) 26,0 (bar) 2,6 (Mpa) 26,0 (bar)
Degree of protection IP24 IP24
Gas connection maximum lenght 8 m 8 m
Gas connection maximum drop 3 m 3 m
ACCESSORIES    
Shelded probe connection cable between units 10m + +
TRANSPORTATION DATA    
Indoor unit (HxDxW) 1340x600x575 mm 1555x600x575 mm
Outdoor unit (HxDxW) 610x350x815 mm 610x350x815 mm
MODEL TC 200 SPLIT TC 201 SPLIT
Declared load profile L L
Energy efficiency class (1) A A
Energy efficiency ƞwh (1) 108,7 % 106,6 %
AEC annual electricity consumption_ACC (1) 942 kWh 961 kWh
Daily electricity consumption Qelec_ACC (2) 4,449 kWh 4,539 kWh
Thermostat temperature settings 55 °C 55 °C
Value of smart 0 0
Storage volume V 201,6 l 194 l
Mixed water at 40°C V40 (2) 259 l 243 l
TECHNICAL CHARACTERISTICS    
COPDHW (A15/W10-55) EN 16147* 2,62 2,57
Working range - air temparature -7 to +35 °C -7 to +35 °C
Heating up Period A7/W10-55* 6:15 h:min 6:08 h:min
Average thickness of insulation 67 mm 67 mm
Standby power input 29 W 30 W
Connections to the watter supply network G1 G1
Netto/gross/with watter 77/89/279 kg 100/112/294 kg
OUTDOOR UNIT    
Dimensions of refrigerant connections liquid- gas Ø6,35 - Ø9,52(1/4”- 3/8”) Ø6,35 - Ø9,52(1/4”- 3/8”)
Net weight (empty) 29 kg 29 kg
Working Air Flow 1800 m3/h 1800 m3/h
Sound power level LWA, outdoors /Sound Pressure on 1m (3) 56/46 dB(A) 56/46 dB(A)
Refrigerant** R134a (GWP 1430) R134a (GWP 1430)
Quantty of refrigiant 1,150 kg 1,150 kg
Design pressure of the circuit (low) 1,0 (Mpa) 10,0 (bar) 1,0 (Mpa) 10,0 (bar) 
Design pressure of the circuit (high) 2,6 (Mpa) 26,0 (bar) 2,6 (Mpa) 26,0 (bar)
Degree of protection IP24 IP24
Gas connection maximum lenght 8 m 8 m
Gas connection maximum drop 3 m 3 m
ACCESSORIES    
Shelded probe connection cable between units 10m + +
TRANSPORTATION DATA    
Indoor unit (HxDxW) 1500x800x800 mm 1500x800x800 mm
Outdoor unit (HxDxW) 610x350x815 mm 610x350x815 mm
MODEL TC 300 SPLIT TC 301 SPLIT
Declared load profile XL XL
Energy efficiency class (1) A A
Energy efficiency ƞwh (1) 116,1 % 109,9 %
AEC annual electricity consumption_ACC (1) 1443 kWh 1525 kWh
Daily electricity consumption Qelec_ACC (2) 6,715 kWh 7,093 kWh
Thermostat temperature settings 55 °C 55 °C
Value of smart 0 0
Storage volume V 295 l 276 l
Mixed water at 40°C V40 (2) 395 l 370 l
TECHNICAL CHARACTERISTICS    
COPDHW (A15/W10-55) EN 16147* 2,84 2,69
Working range - air temparature -7 to +35 °C -7 to +35 °C
Heating up Period A7/W10-55* 10:06 h:min 9:48 h:min
Average thickness of insulation 67 mm 67 mm
Standby power input 26 W 27 W
Connections to the watter supply network G1 G1
Netto/gross/with watter 96/108/391 kg 138/150/414 kg
OUTDOOR UNIT    
Dimensions of refrigerant connections liquid- gas Ø6,35 - Ø9,52(1/4”- 3/8”) Ø6,35 - Ø9,52(1/4”- 3/8”)
Net weight (empty) 29 kg 29 kg
Working Air Flow 1800 m3/h 1800 m3/h
Sound power level LWA, outdoors /Sound Pressure on 1m (3) 56/46 dB(A) 56/46 dB(A)
Refrigerant** R134a (GWP 1430) R134a (GWP 1430)
Quantty of refrigiant 1,150 kg 1,150 kg
Design pressure of the circuit (low) 1,0 (Mpa) 10,0 (bar) 1,0 (Mpa) 10,0 (bar) 
Design pressure of the circuit (high) 2,6 (Mpa) 26,0 (bar) 2,6 (Mpa) 26,0 (bar)
Degree of protection IP24 IP24
Gas connection maximum lenght 8 m 8 m
Gas connection maximum drop 3 m 3 m
ACCESSORIES    
Shelded probe connection cable between units 10m + +
TRANSPORTATION DATA    
Indoor unit (HxDxW) 1890x800x800 mm 1890x800x800 mm
Outdoor unit (HxDxW) 610x350x815 mm 610x350x815 mm
MODEL TC 302 SPLIT TC 306 SPLIT
Declared load profile XL XL
Energy efficiency class (1) A A
Energy efficiency ƞwh (1) 109,9 % 112,4 %
AEC annual electricity consumption_ACC (1) 1525 kWh 1491 kWh
Daily electricity consumption Qelec_ACC (2) 7,093 kWh 6,938 kWh
Thermostat temperature settings 55 °C 55 °C
Value of smart 0 0
Storage volume V 276 l 283 l
Mixed water at 40°C V40 (2) 370 l 381 l
TECHNICAL CHARACTERISTICS    
COPDHW (A15/W10-55) EN 16147* 2,69 2,75
Working range - air temparature -7 to +35 °C -7 to +35 °C
Heating up Period A7/W10-55* 9:48 h:min 9:59 h:min
Average thickness of insulation 67 mm 67 mm
Standby power input 27 W 27 W
Connections to the watter supply network G1 G1
Netto/gross/with watter 139/151/415 kg 122/134/405 kg
OUTDOOR UNIT    
Dimensions of refrigerant connections liquid- gas Ø6,35 - Ø9,52(1/4”- 3/8”) Ø6,35 - Ø9,52(1/4”- 3/8”)
Net weight (empty) 29 kg 29 kg
Working Air Flow 1800 m3/h 1800 m3/h
Sound power level LWA, outdoors /Sound Pressure on 1m (3) 56/46 dB(A) 56/46 dB(A)
Refrigerant** R134a (GWP 1430) R134a (GWP 1430)
Quantty of refrigiant 1,150 kg 1,150 kg
Design pressure of the circuit (low) 1,0 (Mpa) 10,0 (bar) 1,0 (Mpa) 10,0 (bar) 
Design pressure of the circuit (high) 2,6 (Mpa) 26,0 (bar) 2,6 (Mpa) 26,0 (bar)
Degree of protection IP24 IP24
Gas connection maximum lenght 8 m 8 m
Gas connection maximum drop 3 m 3 m
ACCESSORIES    
Shelded probe connection cable between units 10m + +
TRANSPORTATION DATA    
Indoor unit (HxDxW) 1890x800x800 mm 1890x800x800 mm
Outdoor unit (HxDxW) 610x350x815 mm 610x350x815 mm

(1) EU Regulation 812/2013; EN 16147:2010, A verage Climate Conditions (ACC)
(2) EN 16147:2010
(3) EN 12102:2013
(*) by air inlet temparatur e of 7 °C, 89% humidity and 10 °C watter on beginning heated up till 55 °C r egarding to EN16147
(**) this product contains fluorinated greenhouse gases. Hermetically sealed