Integral design allows operation with channelled or surrounding air. Simple forms, made of modern materials, and fitted with electronic LCD touch control, it blends in completely with the rest of the water heater and heat pump product range.
ADVANTAGES:
- Integral design for operation with surrounding or channelled air
- Standard dimensions of air duct connections Ф160
- Several options for connection of the air capture and release duct system
- Airflow control option
- Integrated heating flange with air heating elements
- COP 3,3 ( A7/W10-55; EN16147 )
- LCD electronic touch control allows:
- Temperature adjustment and display
- Display of clock and day of the week
- Display of available amount of hot water
- Timer programming
- Rapid heating
- Heating to a temperature of 75 °C
- “Away/Holiday” setting (when you are away from home for several days)
- Automatic Legionella control system
- Fault/error diagnostics
- Models for operating range:
- +7 °C to+35 °C
- -7 °C to+35 °C
- Design with or without heat exchangers
- High-quality PU insulation for lower heat losses
- Tank made of high-quality steel sheet is protected with enamel coating
- Additional anti-corrosion tank protection with a magnesium anode
- Pocket for temperature sensor of external heat source
- Simple cleaning and maintenance
- Available volumes/capacities: 200 l, 300 l
|
|
|
A (mm) |
1110 |
1110 |
1500 |
1500 |
1500 |
B (mm) |
590 |
590 |
690 |
690 |
690 |
C (mm) |
/ |
630 |
/ |
1020 |
540 |
D (mm) |
/ |
/ |
/ |
/ |
910 |
E (mm) |
/ |
/ |
/ |
/ |
360 |
F (mm) |
985 |
985 |
1375 |
1375 |
1375 |
H (mm) |
1170 |
1170 |
1560 |
1560 |
1560 |
I (mm) |
620 |
620 |
840 |
840 |
840 |
J1 (mm) |
/ |
/ |
/ |
790 |
830 |
J2 (mm) |
/ |
910 |
/ |
1300 |
1300 |
HV |
/ |
G 1" |
/ |
G 1" |
G 1" |
IM |
/ |
G 1" |
/ |
G 1" |
G 1" |
CV |
G 3/4" |
G 3/4" |
G 3/4" |
G 3/4" |
G 3/4" |
VM |
/ |
G 1" |
/ |
G 1" |
G 1" |
TV |
G 1" |
G 1" |
G 1" |
G 1" |
G 1" |
Declared load profile |
L |
L |
XL |
XL |
XL |
Energy efficiency class (1) |
A |
A |
A |
A |
A |
Energy efficiency ƞwh (1) (%) |
124,8 |
127,0 |
135,6 |
134,4 |
134,4 |
AEC annual electricity consumption_ACC (1) (kWh) |
821 |
806 |
1235 |
1247 |
1247 |
Daily electricity consumption Qelec_ACC (2) (kWh) |
3,891 |
3,814 |
5,722 |
5,785 |
5,785 |
Thermostat temperature settings (°C) |
55 |
55 |
55 |
55 |
55 |
Sound power level LWA, indoors (3) (dB(A)) |
59 / 58 |
59 / 58 |
59 / 58 |
59 / 58 |
59 / 58 |
Specific precautions (assembly, install, maintain) |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
When connected as pressurised, use of safety valve is mandatory |
Value of smart |
0 |
0 |
0 |
0 |
0 |
Storage volume V (l) |
208,0 |
194,0 |
295,0 |
276,0 |
276,0 |
Mixed water at 40°C V40 (2) (l) |
265 |
248 |
395 |
368 |
368 |
TECHNICAL CHARACTERISTICS |
|
|
|
|
|
Heating up Period A15 / W10-55* (h:min) |
5:17 |
5:13 |
8:05 |
8:00 |
8:00 |
Heating up Period A7 / W10-55** (h:min) |
6:10 |
6:06 |
9:40 |
9:39 |
9:39 |
Energy consuption by chosen cyclus A15 / W10-55* (kWh) |
3,95 |
3,86 |
5,65 |
5,75 |
5,75 |
Energy consuption by chosen cyclus A7 / W10-55** (kWh) |
4,05 |
3,97 |
5,77 |
5,96 |
5,96 |
COPDHW (A15 / W10-55) EN 16147* |
3,07 |
3,12 |
3,39 |
3,38 |
3,38 |
COPDHW (A7 / W10-55) EN 16147** |
3,00 |
3,06 |
3,33 |
3,30 |
3,30 |
Standby power input according to EN16147** (W) |
28 |
26 |
18 |
20 |
20 |
Refrigiant |
R134a |
R134a |
R134a |
R134a |
R134a |
Quantty of refrigiant (g) |
1.100 |
1.100 |
1.100 |
1.100 |
1.100 |
Working range - air temparature (°C) |
-7/+35 |
-7/+35 |
-7/+35 |
-7/+35 |
-7/+35 |
Working Air Flow (m3/h) |
220-450 |
220-450 |
220-450 |
220-450 |
220-450 |
Pressure Drop by 360 m3/h (60%) (Pa) |
100 |
100 |
100 |
100 |
100 |
ELECTRICAL SPECIFICATIONS |
|
|
|
|
|
Nominal electrical power - compressor (W) |
490 |
490 |
490 |
490 |
490 |
Maximum power consumption (W) |
2490 |
2490 |
2490 |
2490 |
2490 |
Number of electric heaters x power (W) |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
2x1000 |
Voltage/Frequecy (V/Hz) |
230/50 |
230/50 |
230/50 |
230/50 |
230/50 |
Electric protection (A) |
16 |
16 |
16 |
16 |
16 |
Protection |
IP24 |
IP24 |
IP24 |
IP24 |
IP24 |
STORAGE TANK |
|
|
|
|
|
Enamelled steel / Protection Mg anode |
+/+ |
+/+ |
+/+ |
+/+ |
+/+ |
Working pressure (Mpa(bar)) |
0,6(6)/0,9(9)/1(10) |
0,6(6)/0,9(9)/1(10) |
0,6(6)/0,9(9)/1(10) |
0,6(6)/0,9(9)/1(10) |
0,6(6)/0,9(9)/1(10) |
Max working pressure heat exchanger (Mpa(bar)) |
1,2(12) |
1,2(12) |
1,2(12) |
1,2(12) |
1,2(12) |
MAX. TEMPERATURE |
|
|
|
|
|
Hot water tank_heat pump (°C) |
65 |
65 |
65 |
65 |
65 |
Hot water tank_electric heater (°C) |
75 |
75 |
75 |
75 |
75 |
Hot water tank_heat exchanger (°C) |
85 |
85 |
85 |
85 |
85 |
DIMENSIONS AND CONNECTION |
|
|
|
|
|
Height (mm) |
1540 |
1540 |
1960 |
1960 |
1960 |
Width (mm) |
670 |
670 |
670 |
670 |
670 |
Depth (mm) |
690 |
690 |
690 |
690 |
690 |
Connections to the watter supply network |
G1 |
G1 |
G1 |
G1 |
G1 |
Dimensions of air connections (mm) |
Ø160 |
Ø160 |
Ø160 |
Ø160 |
Ø160 |
Heat exchanger surface bottom /top (m2) |
- |
1,45/- |
- |
2,7/- |
1,6/1 |
Heat exchanger volume bottom /top (l) |
- |
9,4/- |
- |
10,2/6,8 |
|
Connections to the heat exchanger |
- |
G1 |
- |
G1 |
G1 |
Netto/gross/with water (kg) |
149/157/365 |
177/185/381 |
164/172/459 |
207/215/480 |
210/218/483 |
TRANSPORT DATA |
|
|
|
|
|
Packaging dimensions (mm) |
800x800x1765 |
800x800x1765 |
800x800x2155 |
800x800x2155 |
800x800x2155 |
(1) EU Regulation 812/2013; EN 16147:2010, A verage Climate Conditions (ACC)
(2) EN 16147:2010
(3) EN 12102:2013 (at 60% ventilator speed -ducted air/ at 40% ventilator speed - air fr om premises, no ducts)
(*) by air inlet temparature of 15 °C, 74% humidity and 10 °C watter on beginning heated up till 55 °C regarding to EN16147
(**) by air inlet temparature of 7 °C, 89% humidity and 10 °C watter on beginning heated up till 55 °C regarding to EN16147
|